Lines Matching defs:intern

78 	spl_SplObjectStorage *intern = spl_object_storage_from_obj(object);  in spl_SplObjectStorage_free_storage()  local
85 static zend_result spl_object_storage_get_hash(zend_hash_key *key, spl_SplObjectStorage *intern, ze… in spl_object_storage_get_hash()
113 static void spl_object_storage_free_hash(spl_SplObjectStorage *intern, zend_hash_key *key) { in spl_object_storage_free_hash()
127 static spl_SplObjectStorageElement* spl_object_storage_get(spl_SplObjectStorage *intern, zend_hash_… in spl_object_storage_get()
150 static spl_SplObjectStorageElement *spl_object_storage_attach_handle(spl_SplObjectStorage *intern, … in spl_object_storage_attach_handle()
177 static spl_SplObjectStorageElement *spl_object_storage_attach(spl_SplObjectStorage *intern, zend_ob… in spl_object_storage_attach()
222 static zend_result spl_object_storage_detach(spl_SplObjectStorage *intern, zend_object *obj) /* {{{… in spl_object_storage_detach()
242 static void spl_object_storage_addall(spl_SplObjectStorage *intern, spl_SplObjectStorage *other) { … in spl_object_storage_addall()
257 spl_SplObjectStorage *intern; in spl_object_storage_new_ex() local
324 spl_SplObjectStorage *intern = spl_object_storage_from_obj(obj); in spl_object_storage_debug_info() local
361 spl_SplObjectStorage *intern = spl_object_storage_from_obj(obj); in spl_object_storage_get_gc() local
410 static bool spl_object_storage_contains(spl_SplObjectStorage *intern, zend_object *obj) /* {{{ */ in spl_object_storage_contains()
433 spl_SplObjectStorage *intern = Z_SPLOBJSTORAGE_P(ZEND_THIS); in PHP_METHOD() local
445 spl_SplObjectStorage *intern = spl_object_storage_from_obj(object); in spl_object_storage_has_dimension() local
464 spl_SplObjectStorage *intern = spl_object_storage_from_obj(object); in spl_object_storage_read_dimension() local
487 spl_SplObjectStorage *intern = spl_object_storage_from_obj(object); in spl_object_storage_write_dimension() local
497 spl_SplObjectStorage *intern = spl_object_storage_from_obj(object); in spl_object_storage_unset_dimension() local
509 spl_SplObjectStorage *intern = Z_SPLOBJSTORAGE_P(ZEND_THIS); in PHP_METHOD() local
538 spl_SplObjectStorage *intern = Z_SPLOBJSTORAGE_P(ZEND_THIS); in PHP_METHOD() local
563 spl_SplObjectStorage *intern = Z_SPLOBJSTORAGE_P(ZEND_THIS); in PHP_METHOD() local
581 spl_SplObjectStorage *intern = Z_SPLOBJSTORAGE_P(ZEND_THIS); in PHP_METHOD() local
608 spl_SplObjectStorage *intern = Z_SPLOBJSTORAGE_P(ZEND_THIS); in PHP_METHOD() local
635 spl_SplObjectStorage *intern = Z_SPLOBJSTORAGE_P(ZEND_THIS); in PHP_METHOD() local
646 spl_SplObjectStorage *intern = Z_SPLOBJSTORAGE_P(ZEND_THIS); in PHP_METHOD() local
663 spl_SplObjectStorage *intern = Z_SPLOBJSTORAGE_P(ZEND_THIS); in PHP_METHOD() local
676 spl_SplObjectStorage *intern = Z_SPLOBJSTORAGE_P(ZEND_THIS); in PHP_METHOD() local
688 spl_SplObjectStorage *intern = Z_SPLOBJSTORAGE_P(ZEND_THIS); in PHP_METHOD() local
701 spl_SplObjectStorage *intern = Z_SPLOBJSTORAGE_P(ZEND_THIS); in PHP_METHOD() local
718 spl_SplObjectStorage *intern = Z_SPLOBJSTORAGE_P(ZEND_THIS); in PHP_METHOD() local
734 spl_SplObjectStorage *intern = Z_SPLOBJSTORAGE_P(ZEND_THIS); in PHP_METHOD() local
751 spl_SplObjectStorage *intern = Z_SPLOBJSTORAGE_P(ZEND_THIS); in PHP_METHOD() local
764 spl_SplObjectStorage *intern = Z_SPLOBJSTORAGE_P(ZEND_THIS); in PHP_METHOD() local
816 spl_SplObjectStorage *intern = Z_SPLOBJSTORAGE_P(ZEND_THIS); in PHP_METHOD() local
935 spl_SplObjectStorage *intern = Z_SPLOBJSTORAGE_P(ZEND_THIS); in PHP_METHOD() local
965 spl_SplObjectStorage *intern = Z_SPLOBJSTORAGE_P(ZEND_THIS); in PHP_METHOD() local
1023 spl_SplObjectStorage *intern; in PHP_METHOD() local
1038 spl_SplObjectStorage *intern = Z_SPLOBJSTORAGE_P(ZEND_THIS); in PHP_METHOD() local
1050 spl_SplObjectStorage *intern; in PHP_METHOD() local
1062 spl_SplObjectStorage *intern; in PHP_METHOD() local
1106 spl_SplObjectStorage *intern = Z_SPLOBJSTORAGE_P(ZEND_THIS); in PHP_METHOD() local
1121 spl_SplObjectStorage *intern = Z_SPLOBJSTORAGE_P(ZEND_THIS); in PHP_METHOD() local
1131 spl_SplObjectStorage *intern = Z_SPLOBJSTORAGE_P(ZEND_THIS); in PHP_METHOD() local
1143 spl_SplObjectStorage *intern; in PHP_METHOD() local
1164 spl_SplObjectStorage *intern; in PHP_METHOD() local
1185 spl_SplObjectStorage *intern; in PHP_METHOD() local
1225 static void spl_multiple_iterator_get_all(spl_SplObjectStorage *intern, int get_type, zval *return_… in spl_multiple_iterator_get_all()
1298 spl_SplObjectStorage *intern; in PHP_METHOD() local
1312 spl_SplObjectStorage *intern; in PHP_METHOD() local